80 resultados para catheter-related bloodstream infection, nosocomial infection, healthcare associated infection, infection control, antimicrobial catheters, healthcare epidemiology, health economics, economic evaluation, cost-effectiveness, health technology assessment

em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Study the semi-quantitative and quantitative technique in the diagnosis of catheter-related infections in newborns and to determine oxacillin resistance in Staphylococcus isolated. It was analyzed 353 catheter tips from 273 newborns in the Neonatal Unit of Hospital FMB. To confirm the diagnosis of infection, were analyzed the clinical data of newborns, the presence of at least one positive blood culture and growth of ≥ 1000 CFU/mL on quantitative culture and/or ³15 UFC on semiquantitative culture, with the same microorganism isolation (species and drug sensitivity) in blood culture and no other focus of infection except the catheter. The disk diffusion technique was used to check similarity of strains and resistance to oxacillin. Of the 353 tips analyzed, 39 were included in this study as the inclusion criteria. The semiquantitative culture was positive in 26 (66.7%) catheters and quantitative culture was positive in 24 (61.5%). Of 273 patients, 19 (6.9%) had a diagnosis of catheter-related bloodstream Infection (CR-BSI). Of the 19 episodes of CR-BSI, S. epidermidis was the predominant etiological agent (84.2%). The resistance to the antibiotic methicillin was found in 14 (73.7%) strains of Staphylococcus. The semiquantitative method was more sensitive (79%) compared with the quantitative method (63%). The use of antibiotics may have influenced the sensitivity of the quantitative method as the microorganisms present in the lumen are exposed to higher concentrations of antibiotics administered via the catheter

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Este estudo prospectivo avaliou os métodos semiquantitativo e qualitativo de cultura de cateter para o diagnóstico de infecção relacionada a cateter (IRC) em recém-nascidos (RN). Foram incluídas pontas de cateteres provenientes de recém-nascidos internados na Unidade Neonatal do Hospital das Clínicas da Faculdade de Medicina de Botucatu, UNESP. Foram utilizadas as técnicas semiquantitativa e qualitativa de cultura de cateter. Para o diagnóstico de IRC, os microrganismos isolados das culturas de cateteres e de hemoculturas periféricas foram identificados e submetidos ao teste de sensibilidade a antimicrobianos. O padrão ouro correspondeu ao diagnóstico de certeza de IRC, com o isolamento do mesmo microrganismo (espécie e perfil de sensibilidade a antimicrobianos) isolado em hemocultura periférica. Foram estudados 85 cateteres provenientes de 63 RN. A cultura semiquantitativa, embora tenha apresentado menor sensibilidade (90%), apresentou uma maior especificidade (71%) em comparação à sensibilidade de 100% e especificidade de 60% encontradas na cultura qualitativa. Através da identificação dos microrganismos obtidos nas culturas de cateteres, observou-se uma predominância de espécies de Estafilococos coagulase-negativa (ECN). A espécie Staphylococcus epidermidis foi a prevalente (77,5%) nos cateteres com culturas semiquantitativas positivas. Dos 11 episódios de IRC diagnosticados, 8 (72,7%) foram associados a espécies de ECN, dos quais 6 eram da espécie S. epidermidis. Também foram detectados dois casos de IRC por S. aureus e um caso por Candida parapsilosis. O método de cultura semiquantitativo cateter apresentou vantagens para o diagnóstico de IRC em RN quando comparado com o método qualitativo tradicional.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Vascular access is the major risk factor for bacteremia, hospitalization, and mortality among hemodialysis (HD) patients. The type of vascular access most associated with bloodstream infection is central venous catheter (CVC). The incidence of catheter-related bacteremia ranges between 0.6 and 6.5 episodes per 1000 catheter days and increases linearly with the duration of catheter use. Given the high prevalence of CVC use and its direct association with catheter-related bacteremia, which adversely impacts morbidity and mortality rates and costs among HD patients, several prevention measures aimed at reducing the rates of CVC-related infections have been proposed and implemented. As a result, a large number of clinical trials, systematic reviews, and meta-analyses have been conducted in order to assess the effectiveness, clinical applicability, and long-term adverse effects of such measures. In the following article, prophylactic measures against CVC-related infections in HD patients and their possible advantages and limitations will be discussed, and the more recent literature on clinical experience with prophylactic antimicrobial lock therapy in HD CVCs will be reviewed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Pós-graduação em Biologia Geral e Aplicada - IBB

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Semiquantitative (Maki) and quantitative (Brun- Buisson) culture techniques were employed in the diagnosis of catheter-related bloodstream infections (CRBSI) in patients who have a short-term central venous catheter (inserted for 30 days). The diagnosis of CRBSI was based on the results of semiquantitative and quantitative culture of material from the removed catheters. Catheter tips (118) from 100 patients were evaluated by both methods. Semiquantitative analysis revealed 34 catheters (28.8%) colonized by ≥15 colonyforming units (cfu), while quantitative cultures (34 catheters, 28.8%) showed the growth of ≥103 cfu/mL. Bacteremia was confirmed in four patients by isolating microorganisms of identical species from both catheters and blood samples. Using the semiquantitative culture technique on short-term central venous catheter tips, we have shown that with a cut-off level of ≥15 cfu, the technique had 100.0% sensitivity, specificity of 68.4%, 25.0% positive predictive value (PPV) and 100.0% negative predictive value (NPV), efficiency of 71.4% and a prevalence of 9.5%. The quantitative method, with a cut-off limit of ≥103 cfu/mL, gave identical values: the sensitivity was 100.0%, specificity 68.4%, positive predictive value (PPV) 25.0%, negative predictive value (NPV) 100.0%, efficiency 71.4% and prevalence 9.5%. We concluded that the semiquantitative and quantitative culture methods, evaluated in parallel, for the first time in Brazil, have similar sensitivity and specificity. Keywords: central venous catheter; semi-quantitative culture; quantitative culture; catheter-related bacteremia.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Cateteres venosos centrais inseridos em pacientes internados em unidade de terapia intensiva foram avaliados por métodos microbiológicos (cultura semi-quantitativa) e microscopia eletrônica de varredura a fim de detectar adesão microbiana e correlacionar com a cultura de sangue. Durante o período de estudo, foram avaliados 59 pacientes com cateter venoso central. A idade dos pacientes, sexo, sítio de inserção e tempo de permanência do cateter foram anotados. O cateter era de poliuretano não tunelizado e de único lúmen. O sangue para cultura foi coletado no momento da remoção do cateter. de 63 pontas de cateteres, 30 (47,6%) foram colonizadas e a infecção encontrada em 5 (23,8%) cateteres. A infecção foi mais prevalente em 26 pacientes (41,3%) com cateteres inseridos em veia subclávia do que nos 3 (3,2%) inseridos em veia jugular. A infecção foi observada com mais freqüência em cateteres com tempo de permanência maior do que sete dias. Os microrganismos isolados incluíram 32 estafilococos coagulase-negativa (29,7%), 61 bactérias Gram-negativas (52,9%), 9 estafilcocos coagulase-positiva (8,3%) e 3 leveduras (2,7%). Como agentes causais de infecções em unidade de terapia intensiva foram isolados E. aerogenes, P. aeruginosa, A. baumannii. Os antimicrobianos com maior atividade in vitro contra as bactérias Gram-negativas foram o imipenem e contra as Gram-positivas vancomicina, cefepime, penicilina, rifampicina e tetraciclina. As análises por microscopia eletrônica de varredura revelaram biofilmes sobre a superfície de todos os cateteres examinados.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This investigation evaluated the effectiveness of an infection control protocol for cleansing and disinfecting removable dental prostheses. Sixty-four dentures were rubbed with sterile cotton swab immediately after they had been taken from patients' mouths. Samples were individually placed in the culture medium and immediately incubated at 37 +/- 2 degreesC. The dentures were scrubbed for 1 min with 4% chlorhexidine, rinsed for 1 min in sterile water and placed for 10 min in one of the following immersion solutions: 4% chlorhexidine gluconate, 1% sodium hypochlorite, Biocide (iodophors) and Amosan (alkaline peroxide). After the disinfection procedures, the dentures were immersed in sterile water for 3 min, reswabbed and the samples were incubated. All samples obtained in the initial culture were contaminated with micro-organisms. All the lower dentures immersed in Biocide showed positive growth, and the upper dentures were positive for growth in six of eight dentures. The 4% chlorhexidine gluconate, 1% sodium hypochlorite and Amosan solutions have been proved effective to reduce the growth of the micro-organisms in the 10 min immersion period. The protocol evaluated in this study seems to be a viable method to prevent cross-contamination between dental personnel and patients.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)